Автор Moody, G. J.
Автор Sanghera, G. S.
Автор Thomas, J. D. R.
Дата выпуска 1987
dc.description Flow injection analysis systems incorporating amperometric bi-enzyme electrodes for glucose and hypoxanthine determination are described. The sensors were based on glucose oxidase-peroxidase for the determination of glucose and xanthine oxidase-peroxidase for the determination of xanthine and hypoxanthine and the enzymes were immobilised on nylon mesh and held over a platinum electrode. The hydrogen peroxide product of the enzymatic catalysis was monitored amperometrically in a three-electrode Stelte cell, adapted for flow injection analysis, after its peroxidase-catalysed reaction with hexacyanoferrate(II).The use of the hexacyanoferrate(II) mediator permitted a low applied potential (â 100 mV vs. Ag-AgCl) to be used, enabling the determination of glucose in blood serum samples without difficult sample pre-treatment. The xanthine oxidase-peroxidase bi-enzyme electrode was used to determine hypoxanthine in fish meat as an indicator of deterioration during storage and the results compared favourably with an alternative spectrophotometric approach recommended by the Analytical Methods Committee (AMC) according to the equation [hypoxanthine]Electrode= 1.01[hypoxanthine]AMC+ 4.0 Ã 10<sup>â 3</sup>, with a correlation coefficient of 0.998.
Формат application.pdf
Издатель Royal Society of Chemistry
Название Chemically immobilised bi-enzyme electrodes in the redox mediated mode for the flow injection analysis of glucose and hypoxanthine
Тип research-article
DOI 10.1039/AN9871200065
Electronic ISSN 1364-5528
Print ISSN 0003-2654
Журнал Analyst
Том 112
Первая страница 65
Последняя страница 70
Выпуск 1

Скрыть метаданые