Автор |
Yolanda Pérez-Jordán, Mercedes |
Автор |
Soldevila, Jose |
Автор |
Salvador, Amparo |
Автор |
Pastor, Agustín |
Автор |
de la Guardia, Miguel |
Дата выпуска |
1999 |
dc.description |
An inductively coupled plasma mass spectrometry (ICP-MS) procedure has been developed for the determination of major elements, such as Mg, Na, K, Ca and Fe, minor elements, such as Al, Cr, Mn, Cu, Zn, Se, Sr, Br and Rb, and trace elements, such as Li, Ti, Ni, As, I, Ba, Pb, Sc, V, Co, Y, Zr, Mo, Sn, Cs, Ga, Nb, Pd, Cd, Sb, Hf, W, Hg, Tl, Th and U, in wines. The results obtained for Na, Mg, Al, Mn, Fe, Co, Zn, Rb and Cs were compared with those found by neutron activation analysis (NAA). Two ICP-MS calibration methodologies were used and results evaluated from spike recovery studies from which an average recovery of 102±20% was found for quantitative mode measurements. Multi-determination, using Be, Ge, In and Bi for the calibration of the ICP-MS sensitivity in the whole mass range and Rh as the internal standard, provided fast and accurate results, whereas the quantitative mode, using a series of external standard solutions, needs more time and consumes more reagent. |
Формат |
application.pdf |
Издатель |
Royal Society of Chemistry |
Название |
Inductively coupled plasma mass spectrometry analysis of wines |
Тип |
research-article |
DOI |
10.1039/a803476a |
Electronic ISSN |
1364-5544 |
Print ISSN |
0267-9477 |
Журнал |
Journal of Analytical Atomic Spectrometry |
Том |
14 |
Первая страница |
33 |
Последняя страница |
39 |
Выпуск |
1 |
Библиографическая ссылка |
Baluja-Santos, Talanta, 1992, 39, 329 |
Библиографическая ссылка |
Augagneur, J. Anal. At. Spectrom., 1996, 11, 713 |
Библиографическая ссылка |
Frank, Anal. Chim. Acta, 1984, 162, 241 |
Библиографическая ссылка |
Thiel, Fresenius J. Anal. Chem., 1997, 357, 553 |
Библиографическая ссылка |
Bodyne-Szalai, Magy. Kem. Foly., 1996, 102, 411 |
Библиографическая ссылка |
López-Artiguez, J. AOAC. Int., 1996, 79, 1191 |
Библиографическая ссылка |
Yang, Fenxi Huaxue, 1991, 19, 362 |
Библиографическая ссылка |
Eschnauer, Mikrochim. Acta, 1989, III, 291 |
Библиографическая ссылка |
Zhu, Fenxi Huaxue, 1988, 16, 556 |
Библиографическая ссылка |
Gu, Fenxi Huaxue, 1987, 15, 1140 |
Библиографическая ссылка |
Voulgaropoulos, Connaiss. Vigne Vin, 1987, 21, 23 |
Библиографическая ссылка |
Zihlmann, Labor Betr., 1987, February, 15 |
Библиографическая ссылка |
Interesse, Z. Lebensm.-Unters.-Forsch., 1985, 181, 470 |
Библиографическая ссылка |
Interesse, Z. Lebensm.-Unters.-Forsch., 1984, 178, 272 |
Библиографическая ссылка |
Moens, J. Anal. At. Spectrom., 1994, 9, 187 |
Библиографическая ссылка |
Stroh, At. Spectrosc., 1994, 15, 100 |
Библиографическая ссылка |
McCurdy, Lab. News, 1992, September, 10 |
Библиографическая ссылка |
Goossens, Fresenius J. Anal. Chem., 1993, 347, 119 |
Библиографическая ссылка |
Goossens, Anal. Chim. Acta, 1994, 293, 171 |
Библиографическая ссылка |
Baxter, Food Chem., 1997, 60, 443 |
Библиографическая ссылка |
Byrne, Mikrochim. Acta, 1984, I, 119 |
Библиографическая ссылка |
May, J. Radioanal. Chem., 1982, 72, 305 |
Библиографическая ссылка |
Brätter, Radiochim. Acta, 1983, 34, 85 |
Библиографическая ссылка |
D. Gawlik and T.Robertson, Irradiation Devices at the Upgraded Research Reactor BER II, Hahn-Meitner Institutut, Berlin, Germany, 1992 |
Библиографическая ссылка |
Soldevila, J. Anal. At. Spectrom., 1998, 13, 803 |
Библиографическая ссылка |
Long, ICP Inf. Newsl., 1991, 16, 460 |