Автор Wu, Zhiyong
Автор Jensen, Henrik
Автор Gamby, Jean
Автор Bai, Xiaoxia
Автор Girault, Hubert H.
Дата выпуска 2004
dc.description A push/pull sample introduction method based on push/pull pressure flow for microfluidic systems (cross, double T and multichannel structures) is presented. This leads to well-defined and controllable sample plugs even when dealing with long channels. By tuning the relative push/pull pressure, it is shown that the size of the sample plug can effectively be controlled. Good signal reproducibility upon continued sample introduction and subsequent chip electrophoresis employing fluorescence detection is demonstrated for different chip geometries (i.e. short channels and long channels). Since the performance of the method is relatively insensitive to chip geometry, it is particularly useful for polymeric prototype microchips as tedious optimization is not required. Furthermore, the push/pull sample introduction is extended to multichannel chips thus demonstrating the possibilities of applying the methodology for realizing single chip high throughput sample analysis.
Формат application.pdf
Издатель Royal Society of Chemistry
Название A flexible sample introduction method for polymer microfluidic chips using a push/pull pressure pump
Тип research-article
DOI 10.1039/b308405a
Electronic ISSN 1473-0189
Print ISSN 1473-0197
Журнал Lab on a Chip
Том 4
Первая страница 512
Последняя страница 515
Аффилиация Wu Zhiyong; Laboratoire d'Electrochimie Physique et Analytique, Ecole Polytechnique Fédérale de Lausanne
Аффилиация Jensen Henrik; Laboratoire d'Electrochimie Physique et Analytique, Ecole Polytechnique Fédérale de Lausanne
Аффилиация Gamby Jean; Laboratoire d'Electrochimie Physique et Analytique, Ecole Polytechnique Fédérale de Lausanne
Аффилиация Bai Xiaoxia; Laboratoire d'Electrochimie Physique et Analytique, Ecole Polytechnique Fédérale de Lausanne
Аффилиация Girault Hubert H.; Laboratoire d'Electrochimie Physique et Analytique, Ecole Polytechnique Fédérale de Lausanne
Выпуск 5
Библиографическая ссылка D. R. Reyes, D. Lossifidis, P.-A. Auroux, A. Manz, Anal. Chem., 2002, 74, 2623, 2636
Библиографическая ссылка P.-A. Auroux, D. Lossifidis, D. R. Reyes, A. Manz, Anal. Chem., 2002, 74, 2637, 2652
Библиографическая ссылка J. P. Alarie, S. C. Jacobson, J. M. Ramsey, Electrophoresis, 2001, 22, 312, 317
Библиографическая ссылка L. M. Fu, R. J. Yang, G. B. Lee, H. H. Liu, Anal. Chem., 2002, 74, 5084, 5091
Библиографическая ссылка S. C. Jacobson, R. Hergenroder, L. B. Koutny, R. J. Warmack, J. M. Ramsey, Anal. Chem., 1994, 66, 1107, 1113
Библиографическая ссылка X. Bai, H. J. Lee, J. S. Rossier, F. Reymond, H. Schafer, M. Wossner, H. H. Girault, Lab Chip, 2002, 2, 45, 49
Библиографическая ссылка H. J. Crabtree, E. C. S. Cheong, D. A. Tilroe, C. J. Backhouse, Anal. Chem., 2001, 73, 4079, 4086
Библиографическая ссылка E. Chmela, M. T. Blom, J. G. E. Gardeniers, A. van den Berg, R. Tijssen, Lab Chip, 2002, 2, 235, 241
Библиографическая ссылка Y. H. Lin, G. B. Lee, C. W. Li, G. R. Huang, S. H. Chen, J. Chromatogr., A, 2001, 937, 115, 125
Библиографическая ссылка Z. L. Fang, Q. Fang, Freseniusâ J. Anal. Chem., 2001, 370, 978, 983
Библиографическая ссылка D. Solignac, M. A. M. Gijs, Anal. Chem., 2003, 75, 1652, 1657
Библиографическая ссылка M. A. Roberts, J. S. Rossier, P. Bercier, H. H. Girault, Anal. Chem., 1997, 69, 2035
Библиографическая ссылка F. Bianchi, F. Wagner, P. Hoffmann, H. H. Girault, Anal. Chem., 2001, 73, 829, 836
Библиографическая ссылка F. Bianchi, Y. Chevolot, H. J. Mathieu, H. H. Girault, Anal. Chem., 2001, 73, 3845, 3853