dc.description |
The influence of electrode temperature on the time delay of electrical breakdown in an argon-filled (13.3 mbar) diode at electrode temperatures of 300, 523 and 673K has been investigated by measuring the electrical breakdown time delay (t<sub>d</sub>) dependence on both the time interval between two successive measurements ( tau ) ('memory curves') and the applied voltages (U<sub>w</sub>). The results obtained show that values of t<sub>d</sub> at 673K are about one order of magnitude smaller than those at 300K, whether cathode or anode was heated. It was shown that the complete curve t<sub>d</sub>=f(U<sub>w</sub>) moved towards smaller values of t<sub>d</sub> with increasing temperature. Conclusions on the change with temperature of the temperature equilibrium concentration of metastables are drawn. |
Формат |
application.pdf |
Издатель |
Institute of Physics Publishing |
Название |
Influence of electrode temperature on the metastable atom concentration in an argon-filled diode |
Тип |
paper |
DOI |
10.1088/0022-3727/14/4/022 |
Electronic ISSN |
1361-6463 |
Print ISSN |
0022-3727 |
Журнал |
Journal of Physics D: Applied Physics |
Том |
14 |
Первая страница |
693 |
Последняя страница |
698 |
Аффилиация |
M M Pejovic; Faculty of Electron. Engng., Nis, Yugoslavia |
Аффилиация |
Dj A Bosan; Faculty of Electron. Engng., Nis, Yugoslavia |
Выпуск |
4 |