Автор M M Pejovic
Автор Dj A Bosan
Дата выпуска 1981-04-14
dc.description The influence of electrode temperature on the time delay of electrical breakdown in an argon-filled (13.3 mbar) diode at electrode temperatures of 300, 523 and 673K has been investigated by measuring the electrical breakdown time delay (t<sub>d</sub>) dependence on both the time interval between two successive measurements ( tau ) ('memory curves') and the applied voltages (U<sub>w</sub>). The results obtained show that values of t<sub>d</sub> at 673K are about one order of magnitude smaller than those at 300K, whether cathode or anode was heated. It was shown that the complete curve t<sub>d</sub>=f(U<sub>w</sub>) moved towards smaller values of t<sub>d</sub> with increasing temperature. Conclusions on the change with temperature of the temperature equilibrium concentration of metastables are drawn.
Формат application.pdf
Издатель Institute of Physics Publishing
Название Influence of electrode temperature on the metastable atom concentration in an argon-filled diode
Тип paper
DOI 10.1088/0022-3727/14/4/022
Electronic ISSN 1361-6463
Print ISSN 0022-3727
Журнал Journal of Physics D: Applied Physics
Том 14
Первая страница 693
Последняя страница 698
Аффилиация M M Pejovic; Faculty of Electron. Engng., Nis, Yugoslavia
Аффилиация Dj A Bosan; Faculty of Electron. Engng., Nis, Yugoslavia
Выпуск 4