Автор L E Gettel
Автор F L Curzon
Дата выпуска 1982-05-14
dc.description By measuring the power balance for high current AC and DC vortex stabilised arcs it has been shown that the radiative efficiencies of AC and DC arcs are comparable to each other at similar power input levels. The electrode power balance has also been determined as a function of the significant arc parameters (current I, gas pressure, flow direction and rate). Further details on electrode heat transport were obtained by measuring the spatial and temporal variations of electrode surface temperature using a two-wavelength pyrometric technique. The heat transfer to the walls and exhaust gas depend linearly on the radiation losses. The former loss is larger than expected from laminar heat flow models indicating that heat losses are enhanced by turbulence in the gas flow. The power balance data confirm that the AC vortex stabilised arc lamp is comparable to the DC arc and has the added prospect of lower electrode erosion because of the smaller average electrode heat fluxes in the AC arc.
Формат application.pdf
Издатель Institute of Physics Publishing
Название Energy transport in DC and AC vortex stabilised arcs
Тип paper
DOI 10.1088/0022-3727/15/5/014
Electronic ISSN 1361-6463
Print ISSN 0022-3727
Журнал Journal of Physics D: Applied Physics
Том 15
Первая страница 845
Последняя страница 865
Аффилиация L E Gettel; Dept. of Phys., Univ. of British Columbia, Vancouver, BC, Canada
Аффилиация F L Curzon; Dept. of Phys., Univ. of British Columbia, Vancouver, BC, Canada
Выпуск 5