Мобильная версия

Доступно журналов:

3 288

Доступно статей:

3 891 637

 

Скрыть метаданые

Автор G Kitis
Автор J W N Tuyn
Дата выпуска 1998-08-21
dc.description Temperature lags between the heating element and the sample are known to exists during a thermoluminescence measurement. The experimental difficulties associated with the temperature lag can be quite serious, when one wants to extract physical information from the glow curves, because it is obviously essential to know the sample's temperature rather than that of the heating element. In the present work approximate relations to estimate the temperature lag between the heating element and the dosemeter and the effective heating rate across the sample are proposed. Preliminary experimental tests of the proposed equations are performed on LiF:Mg, Ti and and on data taken from the literature.
Формат application.pdf
Издатель Institute of Physics Publishing
Название A simple method to correct for the temperature lag in TL glow-curve measurements
Тип paper
DOI 10.1088/0022-3727/31/16/017
Electronic ISSN 1361-6463
Print ISSN 0022-3727
Журнал Journal of Physics D: Applied Physics
Том 31
Первая страница 2065
Последняя страница 2073
Выпуск 16

Скрыть метаданые