Автор M J Usher
Автор I W Buckner
Автор R F Burch
Дата выпуска 1977-12-01
dc.description A miniature, wideband, horizontal-component feedback seismometer has been developed and compared with conventional seismometers. The instrument employs an inverted pendulum of mass 0.04 kg supported with a natural period of 0.6 s and a Q factor of about 20. Displacements of the mass are sensed by a differential capacitive transducer and feedback is applied via an electromagnetic system to maintain the mass stationary with respect to its supports. The instrument has a response defined by feedback from DC to 100 Hz and has a Brownian noise level of 5*10<sup>-10</sup> m s<sup>-2</sup>. Overall dimensions, including an evacuated jacket, are 15 cm*10 cm diameter making it suitable for borehole applications. The instrument has been operated for several weeks with conventional long-period seismometers and has been found to compare satisfactorily.
Формат application.pdf
Издатель Institute of Physics Publishing
Название A miniature wideband horizontal-component feedback seismometer
Тип paper
DOI 10.1088/0022-3735/10/12/020
Print ISSN 0022-3735
Журнал Journal of Physics E: Scientific Instruments
Том 10
Первая страница 1253
Последняя страница 1260
Аффилиация M J Usher; Dept. of Cybernetics, Univ. of Reading, Reading, UK
Аффилиация I W Buckner; Dept. of Cybernetics, Univ. of Reading, Reading, UK
Аффилиация R F Burch; Dept. of Cybernetics, Univ. of Reading, Reading, UK
Выпуск 12

Скрыть метаданые