Автор |
M J Usher |
Автор |
I W Buckner |
Автор |
R F Burch |
Дата выпуска |
1977-12-01 |
dc.description |
A miniature, wideband, horizontal-component feedback seismometer has been developed and compared with conventional seismometers. The instrument employs an inverted pendulum of mass 0.04 kg supported with a natural period of 0.6 s and a Q factor of about 20. Displacements of the mass are sensed by a differential capacitive transducer and feedback is applied via an electromagnetic system to maintain the mass stationary with respect to its supports. The instrument has a response defined by feedback from DC to 100 Hz and has a Brownian noise level of 5*10<sup>-10</sup> m s<sup>-2</sup>. Overall dimensions, including an evacuated jacket, are 15 cm*10 cm diameter making it suitable for borehole applications. The instrument has been operated for several weeks with conventional long-period seismometers and has been found to compare satisfactorily. |
Формат |
application.pdf |
Издатель |
Institute of Physics Publishing |
Название |
A miniature wideband horizontal-component feedback seismometer |
Тип |
paper |
DOI |
10.1088/0022-3735/10/12/020 |
Print ISSN |
0022-3735 |
Журнал |
Journal of Physics E: Scientific Instruments |
Том |
10 |
Первая страница |
1253 |
Последняя страница |
1260 |
Аффилиация |
M J Usher; Dept. of Cybernetics, Univ. of Reading, Reading, UK |
Аффилиация |
I W Buckner; Dept. of Cybernetics, Univ. of Reading, Reading, UK |
Аффилиация |
R F Burch; Dept. of Cybernetics, Univ. of Reading, Reading, UK |
Выпуск |
12 |