A simple experimental capacitance transducer for use in crack opening displacement tests at elevated temperatures
D J Gooch; F J Grimes; D J Gooch; CERL, Leatherhead, UK; F J Grimes; CERL, Leatherhead, UK
Журнал:
Journal of Physics E: Scientific Instruments
Дата:
1975-05-01
Аннотация:
A simple capacitance transducer, suitable for monitoring crack opening displacements (CODS) at elevated temperatures is described. The operation range may be up to several millimetres and so far a stability of +or-1 mu m has been obtained in vacuum at 565 degrees C over periods up to 1000 h.