Comparison of length standards between the CMA and the VNIIM
L Abramova; V Baratov; V Fedorin; L Khavinson; E Latigneva; K Riski; E Ikonen; A Lassila; L Abramova; VNIIM, CMA, HUT; V Baratov; VNIIM, CMA, HUT; V Fedorin; VNIIM, CMA, HUT; L Khavinson; VNIIM, CMA, HUT; E Latigneva; VNIIM, CMA, HUT; K Riski; VNIIM, CMA, HUT; E Ikonen; VNIIM, CMA, HUT; A Lassila; VNIIM, CMA, HUT
Журнал:
Metrologia
Дата:
1996-02-01
Аннотация:
Results are presented from a comparison of a 1 m gauge block and line scale. The largest difference between the average results was 100 nm for the 200 mm line of the scale.