Автор |
F R Bareham |
Дата выпуска |
1960-06-01 |
dc.description |
Eddy-current testing can be used to detect faults in metal tubes by passing the tube through a pair of short solenoidal coils which are energized by an alternating current. The decrease in density of the induced eddy-currents from the outer surface is determined by the frequency of the energizing current and by the electrical properties and dimensions of the tube. Since the eddy-currents flow in a circumferential direction, their distribution is not, as often assumed in the past, the same as when current flows in the direction of the axis. The distribution of eddy-currents flowing circumferentially is given in general terms for non-magnetic tubes and the results can be used in conjunction with a nomogram to determine suitable frequencies for many practical applications. |
Формат |
application.pdf |
Издатель |
Institute of Physics Publishing |
Название |
Choice of frequency for eddy-current tube testing |
Тип |
paper |
DOI |
10.1088/0508-3443/11/6/302 |
Print ISSN |
0508-3443 |
Журнал |
British Journal of Applied Physics |
Том |
11 |
Первая страница |
218 |
Последняя страница |
222 |
Аффилиация |
F R Bareham; The British Non-Ferrous Metals Research Association, London, N.W.1 |
Выпуск |
6 |