Мобильная версия

Доступно журналов:

3 288

Доступно статей:

3 891 637

 

Скрыть метаданые

Автор P N Cooper
Автор K Firth
Автор K G Stephens
Дата выпуска 1961-06-01
dc.description Measurements have been made of the effectiveness of the ring shaped neutron sources for the MERLIN reactor. The emission rate of one neutron source was measured absolutely at the National Physical Laboratory and the remaining sources were compared with this standard. A neutron to gamma ration of (0.7 ± 0.1) × 16<sup>6</sup> n/s per curie of <sup>124</sup>Sb was obtained. The effectiveness of the sources was found by measuring the power generated in a sub-critical core. This result was in reasonable agreement with a calculation, based on two-group diffusion theory.
Формат application.pdf
Издатель Institute of Physics Publishing
Название Use of ring-shaped neutron sources in a research reactor
Тип paper
DOI 10.1088/0508-3443/12/6/308
Print ISSN 0508-3443
Журнал British Journal of Applied Physics
Том 12
Первая страница 298
Последняя страница 299
Аффилиация P N Cooper; Associated Electrical Industries Ltd., Aldermaston, Berks.
Аффилиация K Firth; Associated Electrical Industries Ltd., Aldermaston, Berks.
Аффилиация K G Stephens; Associated Electrical Industries Ltd., Aldermaston, Berks.
Выпуск 6

Скрыть метаданые