Emissivity errors of infra-red pyrometers in relation to spectral response
P M Reynolds; P M Reynolds; The British Non-Ferrous Metals Research Association, London, N.W.1
Журнал:
British Journal of Applied Physics
Дата:
1961-08-01
Аннотация:
The emissivity errors of total, partial and monochromatic radiation pyrometers for use in the temperature range 500-800° K are discussed theoretically. The pyrometer output is expressed as a power law of absolute temperature with an exponent n which varies with temperature and the spectral response of the pyrometer. The emissivity error decreases as n increases. It is shown that n increases as the spectral response of the pyrometer is restricted to shorter wavelengths in the near infra-red region.