Автор D R Allen
Автор H S Peiser
Автор J R Rait
Дата выпуска 1953-09-01
dc.description The safe use of active γ-ray isotope sources for radiography in non-destructive testing laboratories requires efficient containing and handling equipment. The design and construction of a complete set of such tools is described. These comprise (a) source adaptor, plug and container with trolley for safe storage; (b) source-transfer equipment, adjustable rods, stands with quick-release clamps and spider supports for remote handling; and (c) special sighting cones and jigs, used prior to positioning the source for exposure, to avoid unnecessary handling.
Формат application.pdf
Издатель Institute of Physics Publishing
Название Handling equipment and safety containers for use with isotope γ-ray sources for industrial radiography
Тип paper
DOI 10.1088/0508-3443/4/9/303
Print ISSN 0508-3443
Журнал British Journal of Applied Physics
Том 4
Первая страница 268
Последняя страница 273
Аффилиация D R Allen; Hadfields Ltd., Sheffield
Аффилиация H S Peiser; Hadfields Ltd., Sheffield
Аффилиация J R Rait; Hadfields Ltd., Sheffield
Выпуск 9

Скрыть метаданые