Автор |
Eric S Fairley |
Дата выпуска |
1957-03-01 |
dc.description |
The voltage to be measured is applied across the primary of a standard potential transformer and the secondary voltage, at approximately 110 V, is balanced against a direct voltage, using a cathode-ray tube as a null indicator. The direct voltage is measured accurately using a suitable potentiometer and volt-ratio box. Using a cathode-ray tube specially developed for this particular application, an accuracy of better than 0.15% may be readily obtained. An alternative arrangement, in which the potential transformer is replaced by a suitable high voltage resistor divider, is described. |
Формат |
application.pdf |
Издатель |
Institute of Physics Publishing |
Название |
The measurement of peak voltage using a cathode-ray tube |
Тип |
paper |
DOI |
10.1088/0508-3443/8/3/303 |
Print ISSN |
0508-3443 |
Журнал |
British Journal of Applied Physics |
Том |
8 |
Первая страница |
101 |
Последняя страница |
102 |
Аффилиация |
Eric S Fairley; Department of Electrical Engineering, The Royal College of Science and Technology, Glasgow |
Выпуск |
3 |