Мобильная версия

Доступно журналов:

3 288

Доступно статей:

3 891 637

 

Скрыть метаданые

Автор Eric S Fairley
Дата выпуска 1957-03-01
dc.description The voltage to be measured is applied across the primary of a standard potential transformer and the secondary voltage, at approximately 110 V, is balanced against a direct voltage, using a cathode-ray tube as a null indicator. The direct voltage is measured accurately using a suitable potentiometer and volt-ratio box. Using a cathode-ray tube specially developed for this particular application, an accuracy of better than 0.15% may be readily obtained. An alternative arrangement, in which the potential transformer is replaced by a suitable high voltage resistor divider, is described.
Формат application.pdf
Издатель Institute of Physics Publishing
Название The measurement of peak voltage using a cathode-ray tube
Тип paper
DOI 10.1088/0508-3443/8/3/303
Print ISSN 0508-3443
Журнал British Journal of Applied Physics
Том 8
Первая страница 101
Последняя страница 102
Аффилиация Eric S Fairley; Department of Electrical Engineering, The Royal College of Science and Technology, Glasgow
Выпуск 3

Скрыть метаданые