Мобильная версия

Доступно журналов:

3 288

Доступно статей:

3 891 637

 

Скрыть метаданые

Автор T F R Equipe
Дата выпуска 1987-01-01
dc.description Calorimetric measurements inside the vacuum vessel of TFR, using water-cooled shields, give accurate values of the transmission and neutralisation efficiency of the neutral beam injection lines. Measurements during plasma operation give the value of the shine-through fraction of the injected power. The comparison with calculations indicates that the results are close to the expected ones if the usual value of the beam stopping cross-section is slightly increased ( approximately=15%). For TFR experimental conditions, the fast neutral ionization profile throughout the plasma is almost unaffected by this correction and full beam input accountability is experimentally assessed.
Формат application.pdf
Издатель Institute of Physics Publishing
Название Power transmission and shine-through measurements during NBI experiments in TFR by calorimetry inside the torus
Тип paper
DOI 10.1088/0741-3335/29/1/003
Electronic ISSN 1361-6587
Print ISSN 0741-3335
Журнал Plasma Physics and Controlled Fusion
Том 29
Первая страница 37
Последняя страница 42
Аффилиация T F R Equipe; Dept. de Recherches sur la Fusion Controlee, CEN, Fontenay-aux-Roses, France
Выпуск 1

Скрыть метаданые