Автор A V Voronin
Автор K G Hellblom
Дата выпуска 1999-02-01
dc.description A study of a plasma gun (modified Bostic type) with titanium hydride electrodes has been carried out. The total number of released hydrogen atoms was in the range 10<sup>16</sup>-10<sup>18</sup> and the maximum plasma flow velocity was 2.5×10<sup>5</sup> m s<sup>-1</sup>. The ion density near the gun edge reached 1.8×10<sup>20</sup> m<sup>-3</sup> and the electron temperature was around 40 eV as estimated from probe measurements. No species other than hydrogen or titanium were seen in the plasma line radiation. The plasma injector was successfully used for gas pre-ionization in the Extrap T2 reversed-field pinch device (ohmic heating toroidal experiment (OHTE)).
Формат application.pdf
Издатель Institute of Physics Publishing
Название A titanium hydride gun for plasma injection into the T2-reversed field pinch device
Тип paper
DOI 10.1088/0741-3335/41/2/014
Electronic ISSN 1361-6587
Print ISSN 0741-3335
Журнал Plasma Physics and Controlled Fusion
Том 41
Первая страница 293
Последняя страница 302
Выпуск 2