Мобильная версия

Доступно журналов:

3 288

Доступно статей:

3 891 637

 

Скрыть метаданые

Автор E H Cornish
Дата выпуска 1961-03-01
dc.description A discussion is given of the factors involved in the accurate radiation dosimetry of objects bombarded with initially mono-energetic electrons. It is necessary to match the incident electron energy with superficial density in the case of a parallel-sided target in order to attain uniform dose distribution. A preferable procedure is to employ the maximum electron energy available and to use a beam filter of suitable thickness, interposed between the electron source and (in contact with) the target. Such a combination minimizes the maximum overdose given.Another concept described is that of average dose factor, which arises because of the asymmetry of the normal ionization curve.Details of a simply made instrument are given, enabling electron dosimetry calculations to be made by a mechanical analogue of the normal ionization curve. It shows values for optimum electron energy, filter thickness required, and also for average dose factor once the superficial density of the target is known.
Формат application.pdf
Издатель Institute of Physics Publishing
Название Calculator for solving electron irradiation problems
Тип paper
DOI 10.1088/0950-7671/38/3/305
Print ISSN 0950-7671
Журнал Journal of Scientific Instruments
Том 38
Первая страница 82
Последняя страница 85
Аффилиация E H Cornish; Standard Telecommunication Laboratories Ltd., Harlow, Essex
Выпуск 3

Скрыть метаданые