Автор |
K M Swanson |
Автор |
A G Kerswell |
Дата выпуска |
1962-12-01 |
dc.description |
A rotating lead disk with radial collimating slits is placed between the active specimen and the x-ray film. The factor which determines whether the radiograph will be fogged by gamma rays then becomes the activity per unit length of the specimen rather than the total activity. The successful reduction of background fogging by the device is demonstrated. The extension of radiography to the study of very highly active specimens is indicated. |
Формат |
application.pdf |
Издатель |
Institute of Physics Publishing |
Название |
The x-radiography of radioactive specimens using a rotating lead disk with collimating slits |
Тип |
note |
DOI |
10.1088/0950-7671/39/12/438 |
Print ISSN |
0950-7671 |
Журнал |
Journal of Scientific Instruments |
Том |
39 |
Первая страница |
642 |
Последняя страница |
644 |
Аффилиация |
K M Swanson; Radioactive Examination Group, Metallurgy Division, Dounreay Experimental Reactor Establishment, Caithness, Scotland |
Аффилиация |
A G Kerswell; Radioactive Examination Group, Metallurgy Division, Dounreay Experimental Reactor Establishment, Caithness, Scotland |
Выпуск |
12 |