Автор |
J E Brignell |
Дата выпуска |
1963-12-01 |
dc.description |
In response to the need for closer control in direct-stress electrical breakdown investigations in dielectric liquids, an improved test method has been developed. A high-voltage power supply is arranged to give an output voltage which is a slow, linear ramp function of time. The voltage is reset automatically on breakdown, and a recorder and thyratron by-pass circuit complete an automatic system which is capable of making the large number of closely controlled measurements needed for a statistical study. |
Формат |
application.pdf |
Издатель |
Institute of Physics Publishing |
Название |
Automatic measurement of the electric strength of liquid dielectrics |
Тип |
paper |
DOI |
10.1088/0950-7671/40/12/311 |
Print ISSN |
0950-7671 |
Журнал |
Journal of Scientific Instruments |
Том |
40 |
Первая страница |
576 |
Последняя страница |
578 |
Аффилиация |
J E Brignell; Department of Electrical Engineering, Northampton College of Advanced Technology, London |
Выпуск |