Автор |
L M Fisher |
Автор |
A V Kalinov |
Автор |
S E Savel'ev |
Автор |
I F Voloshin |
Автор |
P Haldar |
Автор |
U Balachandran |
Дата выпуска |
1999-01-01 |
dc.description |
We present here results of our study of the 5 m long AC transmission line model with 1 kA current capability at 77 K. Primary attention was paid to the current characteristics and AC losses in individual tapes and in the core of the cable. Problems of tape transposition are considered. Our study was undertaken in several stages. At the beginning, we investigated current capability and AC losses in individual Bi-2223/Ag tapes. The goal was to determine how many tapes were needed to construct a 5 m long transmission line model with a current capability of kA; we then evaluated total AC losses in the model. Subsequently, we designed a current core for the power cable and a cryogenic envelope to test the cable's performance. |
Формат |
application.pdf |
Издатель |
Institute of Physics Publishing |
Название |
Losses in Bi-2223/Ag tapes and in the 1 kA AC transmission line model |
Тип |
paper |
DOI |
10.1088/0953-2048/12/1/006 |
Electronic ISSN |
1361-6668 |
Print ISSN |
0953-2048 |
Журнал |
Superconductor Science and Technology |
Том |
12 |
Первая страница |
24 |
Последняя страница |
35 |
Выпуск |
1 |