Автор L J W Graham
Дата выпуска 1990-05-01
dc.description Constant-current anemometers operating as resistance thermometers are ideally suited for measurement of stream temperature fluctuations. In order to extend their limited frequency response due to the thermal inertia of the wire, open-loop compensation using a zero-pole network is often used. This method becomes unsatisfactory for unsteady flows with large velocity changes as the time constant of the wire changes significantly from instant to instant. An instantaneous velocity-dependent compensation method is described for use with a velocity-temperature probe. Once set, the compensator time constant matches the wire time constant at all times. Limits for good compensation are presented.
Формат application.pdf
Издатель Institute of Physics Publishing
Название A fully compensated hot/cold wire anemometer system for unsteady flow velocity and temperature measurements
Тип paper
DOI 10.1088/0957-0233/1/5/009
Electronic ISSN 1361-6501
Print ISSN 0957-0233
Журнал Measurement Science and Technology
Том 1
Первая страница 425
Последняя страница 430
Аффилиация K Bremhorst; Dept. of Mech. Eng., Queensland Univ., St Lucia, Qld., Australia
Аффилиация L J W Graham; Dept. of Mech. Eng., Queensland Univ., St Lucia, Qld., Australia