Мобильная версия

Доступно журналов:

3 288

Доступно статей:

3 891 637

 

Скрыть метаданые

Автор O Soppart
Автор J I Baumbach
Дата выпуска 2000-10-01
dc.description The drift tube is the most crucial part of an ion mobility spectrometer (IMS), as it is here that the desired separation process of different ionic species takes place. A homogeneous electric field is assumed inside the drift tube, enabling an exact calculation of the mobilities of ionic species formed. For verification of this assumption, the electric field inside a drift tube was examined by means of a field simulation program, using an IMS developed at the Institute of Spectrochemistry and Applied Spectroscopy as an example. A refined design of the drift tube was developed, yielding a dramatic improvement in the resolution achieved. The influences of geometric variations in the drift tube, as well as metallic encapsulation neighbouring the drift tube, on the field homogeneity are estimated.
Формат application.pdf
Издатель Institute of Physics Publishing
Название Comparison of electric fields within drift tubes for ion mobility spectrometry
Тип paper
DOI 10.1088/0957-0233/11/10/308
Electronic ISSN 1361-6501
Print ISSN 0957-0233
Журнал Measurement Science and Technology
Том 11
Первая страница 1473
Последняя страница 1479
Аффилиация O Soppart; Institute of Spectrochemistry and Applied Spectroscopy (ISAS), Bunsen-Kirchhoff-Strasse 11, D-44139 Dortmund, Germany
Аффилиация J I Baumbach; Institute of Spectrochemistry and Applied Spectroscopy (ISAS), Bunsen-Kirchhoff-Strasse 11, D-44139 Dortmund, Germany
Выпуск 10