Мобильная версия

Доступно журналов:

3 288

Доступно статей:

3 891 637

 

Скрыть метаданые

Автор R S van Dyck Jr
Автор D L Farnham
Автор P B Schwinberg
Дата выпуска 1995-01-01
dc.description The Penning trap mass spectrometer at the University of Washington is described along with the relevant detection mechanisms and the systematic shifts associated with the finite energies in the normal modes of the trapped particle. The cyclotron frequency for the particle-of-interest is compared with the corresponding frequency of a single trapped carbon ion (usually C<sup>6+</sup>). Upon correcting for lost electrons and their binding energies, the relative mass ratio then becomes the atomic mass for the particle-of-interest. As a recent example, the value of the electron's "atomic mass" has been measured to be M<sub>e</sub> = 0.000 548 579 911 7(17) u and the corresponding proton–electron mass ratio becomes m<sub>p</sub>/m<sub>e</sub> = 1836.152 664 6 (58).
Формат application.pdf
Издатель Institute of Physics Publishing
Название Precision mass measurements in the UW-PTMS and the electron's "atomic mass"
Тип paper
DOI 10.1088/0031-8949/1995/T59/017
Electronic ISSN 1402-4896
Print ISSN 0031-8949
Журнал Physica Scripta
Том 1995
Первая страница 134
Последняя страница 143
Аффилиация R S van Dyck Jr; University of Washington, Department of Physics, FM-15, Seattle, Washington 98195, USA
Аффилиация D L Farnham; University of Washington, Department of Physics, FM-15, Seattle, Washington 98195, USA
Аффилиация P B Schwinberg; University of Washington, Department of Physics, FM-15, Seattle, Washington 98195, USA
Выпуск T59

Скрыть метаданые