Автор |
Ryutaro Takahashi |
Автор |
Koji Arai |
Автор |
the TAMA collaboration |
Дата выпуска |
2002-04-07 |
dc.description |
The vibration isolation system for TAMA300 has a vibration isolation ratio large enough to achieve the requirement in the observation band around 300 Hz. At a lower frequency range, it is necessary to reduce the large fluctuation of mirrors for stable operation of the interferometer. With this aim, the mirror suspension systems were modified and an active vibration isolation system using pneumatic actuators was installed. These improvements contributed to the realization of a continuous interferometer lock for more than 24 h. |
Формат |
application.pdf |
Издатель |
Institute of Physics Publishing |
Название |
Improvement of the vibration isolation system for TAMA300 |
Тип |
paper |
DOI |
10.1088/0264-9381/19/7/350 |
Electronic ISSN |
1361-6382 |
Print ISSN |
0264-9381 |
Журнал |
Classical and Quantum Gravity |
Том |
19 |
Первая страница |
1599 |
Последняя страница |
1604 |
Аффилиация |
Ryutaro Takahashi; National Astronomical Observatory, Mitaka, Tokyo 181-8588, Japan |
Аффилиация |
Koji Arai; National Astronomical Observatory, Mitaka, Tokyo 181-8588, Japan |
Аффилиация |
the TAMA collaboration; National Astronomical Observatory, Mitaka, Tokyo 181-8588, Japan |
Выпуск |
7 |