Мобильная версия

Доступно журналов:

3 288

Доступно статей:

3 891 637

 

Скрыть метаданые

Автор Olivier Véziant
Автор the VIRGO Collaboration
Дата выпуска 2003-09-07
dc.description This paper describes the calibration procedures developed for the commissioning of the VIRGO central interferometer, as well as their main results obtained during the engineering runs that occurred during that phase. The issue of the detector response monitoring is also addressed, and a preliminary test to produce reconstructed data is reported.
Формат application.pdf
Издатель Institute of Physics Publishing
Название Calibration of the VIRGO central interferometer
Тип paper
DOI 10.1088/0264-9381/20/17/314
Electronic ISSN 1361-6382
Print ISSN 0264-9381
Журнал Classical and Quantum Gravity
Том 20
Первая страница S711
Последняя страница S720
Аффилиация Olivier Véziant ; LAPP, Chemin de Bellevue, 74941 Annecy-le-Vieux, France; Traversa H di via Macerata, 56021 San Stefano a Macerata, Cascina (Pisa), Italy
Аффилиация the VIRGO Collaboration; LAPP, Chemin de Bellevue, 74941 Annecy-le-Vieux, France; Traversa H di via Macerata, 56021 San Stefano a Macerata, Cascina (Pisa), Italy
Выпуск 17

Скрыть метаданые