Автор |
Taylor, Richard |
Дата выпуска |
1990 |
dc.description |
Echocardiographic techniques have been used extensively in the noninvasive evaluation of mitral stenosis. Although mitral valve area can be reliably predicted by two-dimensional echocardiography (2DE) in selected patients, neither M-mode nor 2DE techniques provide any direct hemodynamic information. The subsequent utilization of Doppler techniques allows for interrogation of coexistent blood flow alterations and an estimate of the pressure gradient across the mitral valve using the modified Bernoulli equation. Since the pressure gradient is found to vary with flow volume, an additional Doppler technique using the concept of pressure half-time provides an assessment of the severity of mitral stenosis that is related to mitral valve area and independent of hemodynamic factors. Although several studies reporting good reliability have contributed to the widespread acceptance of the pressure half-time concept, recent reports have indicated significant limitations with the pressure half-time method leading to inaccuracies and poor reliability in predicting the mitral valve area. This review discusses the development of the pressure half-time concept and the implications of these recent research findings on the critical use of the Doppler pressure half-time method to estimate the mitral valve area. |
Издатель |
Sage Publications |
Тема |
Doppler |
Тема |
pressure half-time |
Тема |
pressure gradient |
Тема |
compliance |
Название |
Assessing Mitral Stenosis with Doppler Echocardiography |
Тип |
Journal Article |
DOI |
10.1177/875647939000600404 |
Print ISSN |
8756-4793 |
Журнал |
Journal of Diagnostic Medical Sonography |
Том |
6 |
Первая страница |
219 |
Последняя страница |
223 |
Аффилиация |
Taylor, Richard, Department of Cardiology, Logan General Hospital, Logan, West Virginia; Cardiac Laboratory, Logan General Hospital, Logan, WV 25601. |
Выпуск |
4 |
Библиографическая ссылка |
1. Weyman AE. Cross-Sectional Echocardiography. Philadelphia, PA, Lea & Febiger, 1982, pp 151-162. |
Библиографическая ссылка |
2. Feigenbaum H. Echocardiography, ed 4. Philadelphia, PA, Lea & Febiger, 1986, pp 249-262. |
Библиографическая ссылка |
3. DeMaria AN, Miller RR, Amsterdam EA, Markson W. Mason DT. Mitral valve early diastolic closing velocity in the echocardiogram: relation to sequential diastolic flow and ventricular compliance. Am J Cardiol 1976;37:693-701. |
Библиографическая ссылка |
4. Nichol PN, Gilbert BW, Kisslo JA. Two-dimensioal echocardiographic assessment of mitral stenosis. Circulation 1977;55:120-128. |
Библиографическая ссылка |
5. Martin RP, Rakowski H, Kleiman JH, et al. Reliability and reproducibility of two-dimensional echocardiographic measurement of the stenotic mitral valve orifice area. Am J Cardiol 1979;43:560-568. |
Библиографическая ссылка |
6. Smith MD, Handshoe R, Handshoe S. et al. Comparative accuracy of two-dimensional echocardiographic and Doppler pressure half-time methods in assessing severity of mitral stenosis in patients with and without prior commissurotomy. Circulation 1986;73:100-107. |
Библиографическая ссылка |
7. Bryg RJ, Williams GA, Labovitz AJ, et al. Effect of atrial fibrillation and mitral regurgitation on calculated mitral valve area in mitral stenosis. Am J Cardiol 1986;57:634-638. |
Библиографическая ссылка |
8. Stamm RB, Martin RP. Quantification of pressure gradients across stenotic valves by Doppler ultra-sound. J Am Coll Cardiol 1983;2:707-718. |
Библиографическая ссылка |
9. Adhar GC, Nanda NC. Adult valvular heart disease. Echocardiography 1984;1:219-241. |
Библиографическая ссылка |
10. Hatle L, Brubakk A, Tromsdal A, Angelsen B. Noninvasive assessment of pressure drop in mitral stenosis by Doppler ultrasound. Br Heart J 1978;40:131-140. |
Библиографическая ссылка |
11. Hatle L, Angelsen B, Tromsdal A. Noninvasive assessment of atrioventricular pressure half-time by Doppler ultrasound. Circulation 1979;60:1096-1103. |
Библиографическая ссылка |
12. Hatle L, Angelsen B. Doppler Ultrasound in Cardiology: Physical Principles and Clinical Applications. Philadelphia, PA, Lea & Febiger, 1983, pp 76-88. |
Библиографическая ссылка |
13. Adams DB. Adult Echocardiography. Stockton, CA, Advanced Ultrasound Seminars, 1988, pp 37-44. |
Библиографическая ссылка |
14. Libanoff AJ, Rodbard S. Atrioventricular pressure half-time: Measurement of mitral valve orifice area. Circulation 1968;38:144-150. |
Библиографическая ссылка |
15. Wilkins GT, Thomas JD, Abascal V, et al. Failure of the Doppler pressure half-time to accurately demonstrate change in mitral valve area following percutaneous mitral valvuloplasty (abstract). J Am Coll Cardiol 1987;9:218-218. |
Библиографическая ссылка |
16. Thomas JD, Weyman AE. Doppler mitral pressure half-time: A clinical tool in search of theoretical justification. J Am Coll Cardiol 1987;10:923-929. |
Библиографическая ссылка |
17. Loyd D, Eng D, Ask P, Wranne B. Pressure half-time does not always predict mitral valve area correctly. J Am Soc Echo 1988;1:313-321. |
Библиографическая ссылка |
18. Karp K, Teien D, Bjerle P.Eriksson P. Reassessment of valve area determinations in mitral stenosis by the pressure half-time method: Impact of left ventricular stiffness and peak diastolic pressure difference. J Am Coll Cardiol 1989;13:594-599. |
Библиографическая ссылка |
19. Chen C, Wang Y, Guo B, Lin Y. Reliability of the Doppler pressure half-time method for assessing effects of percutaneous mitral balloon valvuloplasty. J Am Coll Cardiol 1989;13:1309-1313. |
Библиографическая ссылка |
20. Nakatani S, Masuyama T, Kodama K, et al. Value and limitation of Doppler echocardiography in the quantification of stenotic mitral valve area comparison of the pressure half-time and the continuity equation methods. Circulation 1988;77:78-85. |