Мобильная версия

Доступно журналов:

3 288

Доступно статей:

3 891 637

 

Скрыть метаданые

Автор Wheeldon, D.
Автор Bethune, D.
Дата выпуска 1987
dc.description In the course of developing a technique for heart and lung transplantation a 6 kg Rhesus monkey model was used. We required a low prime circuit, because it was difficult to obtain donor blood for these animals, which was also capable of supporting the circulation for up to two hours. We describe a system incorporating a semidisposable bubble oxygenator, run under controlled negative pressure with very short blood lines. This arrangement allows for a priming volume of 110 ml with good venous drainage control. The principle could be exploited for use with paediatric extracorporeal systems.
Издатель Sage Publications
Название A low prime extracorporeal system for small patients: a primate model
Тип Journal Article
DOI 10.1177/026765918700200106
Print ISSN 0267-6591
Журнал Perfusion
Том 2
Первая страница 35
Последняя страница 38
Аффилиация Wheeldon, D., Papworth Hospital, Cambridge
Аффилиация Bethune, D., Papworth Hospital, Cambridge
Выпуск 1
Библиографическая ссылка Barratt-Boyes BG, Neutze JM, Seelye ER, Simpson M.Complete correction of cardiovascular malformations in the first year of life. Prog in Cardiovasc Dis1972; 15: 229-36.
Библиографическая ссылка Bourgeois BF , Donath A., Paunier L., Rouge JC Effects of cardiac surgery on renal function in children. J Thorac Cardiovasc Surg 1979 ; 77(2): 283-87.
Библиографическая ссылка Hill JD, Aguilar MJ, Baranco A., de Lanerolle P., Gerbode F.Neurological manifestations of cardiac surgery. Ann Thorac Surg1969; 7: 409-19.
Библиографическая ссылка Orr MD, Blenco JWAutotransfusion of concentrated selected washed red cells from the surgical field: a biochemical and physiological comparison with homologous cell transfusion . Proceedings Blood Conservation Institute 1978.
Библиографическая ссылка Cohen LH, Fosberg AM, Anderson WP, Collins JJThe effects of phlebotomy, haemodilution and autologous transfusion on systemic oxygenation and whole blood utilization in open heart surgery. Chest1975; 68(3): 283.
Библиографическая ссылка Vroman L., Adams AL, Klings M., Fischer G.Fibrinogen, globulin, albumin and plasma at interfaces. Adv Chemistry1975; 145: 255.
Библиографическая ссылка Edmunds LH, Addonizio PVPlatelet physiology during cardiopulmonary bypass. In: Utley JR ed. Pathophysiology and techniques of cardiopulmonary bypass. London: Williams and Wilkins , 1982.
Библиографическая ссылка Kay ABSome complications associated with the administration of blood and blood products . Clin Haematol 1976; 5(1): 165.
Библиографическая ссылка Boulanger M.Levels of circulating norepinephrine and epinephrine before, during and after cardiopulmonary bypass in man. Survey Anesthesiol1977; 21: 48-53.
Библиографическая ссылка Doenicke A. , Grote B., Lorenz W. Blood and blood substitutes. Br J Anaesth 1977; 49: 681-88.
Библиографическая ссылка Proctor E., Fernando ARA range of researcn oxygenators for experimental cardiopulmonary bypass. J Surg Research1973; 15: 112-16.
Библиографическая ссылка Tobias MA, Fryer JMWhich priming fluids? In: Longmore DB ed. Towards safer cardiac surgery. England: M.T.P. Press, 1981.

Скрыть метаданые