Мобильная версия

Доступно журналов:

3 288

Доступно статей:

3 891 637

 

Скрыть метаданые

Автор Cromer, Michael, J
Автор Wolk, Dennis, R
Дата выпуска 1998
dc.description Reduction in circuit prime during cardiopulmonary bypass has benefits for the patient with a low body surface area, anemia, patient refusal to receive blood products, and aids the practitioner’s goal to minimize exposure to blood products. Described here is a simple, low-cost technique that has been shown to decrease priming volume in any bypass circuit and allow a significant increase in ‘on bypass hemoglobin’.
Издатель Sage Publications
Название A minimal priming technique that allows for a higher circulating hemoglobin on cardiopulmonary bypass
Тип Journal Article
DOI 10.1177/026765919801300505
Print ISSN 0267-6591
Журнал Perfusion
Том 13
Первая страница 311
Последняя страница 313
Аффилиация Cromer, Michael, J, St Joseph’s Hospital of Atlanta, Atlanta, Georgia
Аффилиация Wolk, Dennis, R, St Joseph’s Hospital of Atlanta, Atlanta, Georgia
Выпуск 5
Библиографическая ссылка Palanzo DA, Manley NJ, Montessano RMet al.Potential problems when using the new lower-prime hollow-fibre membrane oxygenators with uncoated stainless steel heat exchangers. Perfusion1996; 11: 481-485.
Библиографическая ссылка Babka RM, Petress J, Briggs R, Helsel R, Mack J.Conventional hemofiltration during routine coronary bypass surgery. Perfusion1997; 12: 187-192.
Библиографическая ссылка Sakert T, Gil W, Rosenburg Iet al.Cell saver efficacy for routine coronary artery bypass surgery. Perfusion1996; 11: 71-77.
Библиографическая ссылка DeBois W.Significant pump prime reduction decreases the need for homologous transfusion. Proc Am Acad Cardiovasc Perfusion1997; 18: 81-83.
Библиографическая ссылка Gravlee GP, Davis RF, Utley JR.Cardiopulmonary bypass principles and practice. Baltimore, MD: Williams & Wilkins, 1993: 124-137.
Библиографическая ссылка DeSomer F, Foubert L, Poelaert J, Dujardin D, Van Nooten G, Francois K.Low extracorporeal priming volumes for infants: a benefit?Perfusion1996; 11: 455-460.

Скрыть метаданые