Мобильная версия

Доступно журналов:

3 288

Доступно статей:

3 891 637

 

Скрыть метаданые

Автор Rosenberg, Norman J.
Автор Brown, K. W.
Дата выпуска 1970
dc.description The performance of the Van Bavel‐Myers lysimeter has been improved in two units installed at Mead, Nebraska. The units function according to design specifications (0.01 mm precision; 0.05 mm accuracy) after the following modifications were made: (1) provide drainage to maintain underground portions of the lysimeter in a water free condition, (2) relocate the electrical junctions to assure high electrical resistance between ground and the strain gage load cell, and (3) make mechanical damping devices accessible for cleaning and adjustment.
Формат application.pdf
Копирайт Copyright 1970 by the American Geophysical Union.
Название Improvements in the Van Bavel‐Myers Automatic Weighing Lysimeter
Тип shortCommunication
DOI 10.1029/WR006i004p01227
Electronic ISSN 1944-7973
Print ISSN 0043-1397
Журнал Water Resources Research
Том 6
Первая страница 1227
Последняя страница 1229
Выпуск 4
Библиографическая ссылка Black, T. A., G. W.Thurtell, C. B.Tanner, Hydraulic load‐cell lysimeter, construction, calibration and tests, Soil Sci. Soc. Amer. Proc., 32, 623–629, 1968.
Библиографическая ссылка Ekern, P. C., Pilot evapotranspiration study: Lysimeter design, Completion RepOWRR Project A‐010‐HI Hawaii, 25, 1967.
Библиографическая ссылка Grebet, P., Evapotranspiration pesable par dynamomètres électroniques, Proc. French Acad. Agr., 1026–1032 10 November, 1965.
Библиографическая ссылка Konstantinov, A. R., Evaporation in nature,1963, (Transl. from Russian,1966),, 523 pp.,U. S. Dep. Commer. Rep. TT‐51015. (Clearing house forFederal Scientific and Technical Information,Springfield, Virginia 22151.).
Библиографическая ссылка Libby, F. J., P. R.Nixon, A portable lysimeter adaptable to a wide range of site situations, Int. Ass. Sci. Hydrol. Comm. Evaporation Publ., 62, 153–158, 1962.
Библиографическая ссылка Pruitt, W. O., D. E.Angus, Large weighing lysimeter for measuring evapotranspiration, Trans. Amer. Soc. Agr. Eng., 32, 13–18, 1960.
Библиографическая ссылка Ritchie, J. T., E.Burnett, A precision weighing lysimeter for row crop water use studies, Agron. J., 60, 545–549, 1968.
Библиографическая ссылка Rose, C. W., G. F.Byrne, J. E.Begg, An accurate hydraulic lysimeter with remote weight recording, CSIRO (Aust.) Div. Land Res. Tech. Pap., 27, 31, 1966.
Библиографическая ссылка Van Bayel, C. H. M., andL. E.Myers, An automatic weighing lysimeter,Agr. Eng.,43,580–583, 587–588,1962.

Скрыть метаданые