dc.description A range of lithium-drifted silicon radiation detectors is described. Areas up to 8 cm<sup>2</sup> and thicknesses up to 0.6 cm have been achieved. At - 20°C, a resolution of 8 kev full width half maximum was obtained on 661 kev beta particles using a 1 cm<sup>2</sup> detector 0.1 cm thick. The performance of the detectors is discussed in relation to other device parameters.
Формат application.pdf
Издатель Institute of Physics Publishing
Название The design and application of lithium drift silicon diodes as nuclear radiation detectors
Тип paper
DOI 10.1088/0950-7671/42/12/308
Print ISSN 0950-7671
Журнал Journal of Scientific Instruments
Том 42
Первая страница 862
Последняя страница 864
Аффилиация P E Gibbons; Electronics Division, Atomic Energy Research Establishment, Harwell, Didcot, Berks