Автор |
Garg, Arun |
Автор |
Chaffin, Don B. |
Дата выпуска |
1975 |
dc.description |
AbstractA computer based three dimensional strength model was used to predict hand forces at 38 different positions for a seated operator. These predictions were compared with the forces exerted by 71 male subjects. Error coefficients of variation averaged from 0.27 to 0.49, and correlation coefficients between the measured and predicted hand forces averaged from 0.93 to 0.97. The hip height predictions proved more accurate than the shoulder height predictions. |
Формат |
application.pdf |
Издатель |
Taylor & Francis Group |
Копирайт |
Copyright Taylor and Francis Group, LLC |
Название |
A Biomechanical Computerized Simulation of Human Strength |
Тип |
research-article |
DOI |
10.1080/05695557508974978 |
Print ISSN |
0569-5554 |
Журнал |
A I I E Transactions |
Том |
7 |
Первая страница |
01 |
Последняя страница |
15 |
Аффилиация |
Garg, Arun; The University of Michigan |
Аффилиация |
Chaffin, Don B.; The University of Michigan |
Выпуск |
1 |