dc.description From the viewpoint of hard tissue response to implant materials, calcium phosphates are probably the most compatible materials presently known. During the last few years, much attention has been paid to hydroxyapatite and β-tricalcium phosphate as potential biomaterials for bone substitute. A good implantation of biomaterials in the skeleton is to reach full integration of non-living implant with living bone. The aim of this study is to compare the resorption kinetics of four kinds of calcium phosphate ceramics: hydroxyapatite (Ca<sub>10</sub>(PO<sub>4</sub>)<sub>6</sub>(OH)<sub>2</sub>), hydroxyapatite doped with manganese or zinc and a composite material of 75% hydroxyapatite and 25% β-tricalcium phosphate (Ca<sub>3</sub>(PO<sub>4</sub>)<sub>2</sub>). Cylinders (5–6 mm in diameter) of these ceramics were packed into holes made in the femur diaphysis of mature ovine. At 2, 4, 8, 12, 16, 20, 28, 36 and 48 weeks after the operation, bone/implant interface was embedded in polymethylmethacrylate. We used the PIXE method (particle induced X-ray emission) to measure the distribution of mineral elements (Ca, P, Sr, Zn, Mn and Fe) at the bone/implant interface. At 4, 8, 16, 28 and 48 weeks after implantation we studied a biopsy of the ceramics by neutron activation method. Then, we have a global measurement of mineral elements in the biomaterial. The results showed that the resorption kinetics of hydroxyapatite doped with zinc was faster than that of the three other bioceramics.
Формат application.pdf
Издатель EDP Sciences
Копирайт © EDP Sciences, 1999
Название Resorption kinetics of four hydroxyapatite-based ceramics by particle induced X-ray emission and neutron activation analysis
Тип research-article
DOI 10.1051/epjap:1999172
Electronic ISSN 1286-0050
Print ISSN 1286-0042
Журнал The European Physical Journal Applied Physics
Том 6
Первая страница 205
Последняя страница 215
Аффилиация Jallot E.; Laboratoire de Microscopie Électronique, 21 rue Clément Ader, 51685 Reims Cedex 2, France
Аффилиация Irigaray J. L.; Laboratoire de Physique Corpusculaire de Clermont-Ferrand, IN2P3/CNRS, 63177 Aubière Cedex, France
Аффилиация Oudadesse H.; Laboratoire de Physique Corpusculaire de Clermont-Ferrand, IN2P3/CNRS, 63177 Aubière Cedex, France
Аффилиация Brun V.; Laboratoire de Physique Corpusculaire de Clermont-Ferrand, IN2P3/CNRS, 63177 Aubière Cedex, France
Аффилиация Weber G.; Institut de Physique Nucléaire Expérimentale, B 15, Sart Tilman, 4000 Liège, Belgium
Аффилиация Frayssinet P.; Société industrielle Bioland, 132 route d'Espagne, 31100 Toulouse, France