Tracer diffusion of <sup>60</sup>Co and <sup>63</sup>Ni in amorphous NiZr alloy
Hoshino, K.; Averback, R. S.; Hahn, H.; Rothman, S. J.; Hoshino K.; Department of Materials Science and Engineering and Materials Research Laboratory, University of Illinois at Urbana–Champaign, Illinois 61801; Averback R. S.; Department of Materials Science and Engineering and Materials Research Laboratory, University of Illinois at Urbana–Champaign, Illinois 61801; Hahn H.; Materials Science Division, Argonne National Laboratory, Argonne, Illinois 60439; Rothman S. J.; Materials Science Division, Argonne National Laboratory, Argonne, Illinois 60439
Журнал:
Journal of Materials Research
Дата:
1988
Аннотация:
Tracer diffusion of <sup>60</sup>Co and <sup>63</sup>Ni in the amorphous alloy NiZr near the equiatomic composition has been measured in the temperature range between 486 and 641 K using the ion-beam sputter-sectioning technique for serial sectioning. The temperature dependence for the diffusivities of Co and Ni in a-NiZr exhibit Arrhenius behavior; these can be expressed as follows: D<sup>∗</sup><sub>co</sub> = 3.6 × 10<sup>−7</sup> exp [− (135 ± 14) kJ mol<sup>−1</sup> /RT] m<sup>2</sup>/s and D<sup>∗</sup><sub>Ni</sub> = 1.7 × 10<sup>−7</sup> exp [− (140 ± 9) kJ mol<sup>−1</sup> /RT] m<sup>2</sup>/s. The values of D<sup>∗</sup><sub>Ni</sub> are in good agreement with those measured by the Rutherford backscattering technique. The measured diffusivities were independent of time, indicating that no relaxation took place during diffusion.
317.3Кб